How to measure roof pitch, rise, run, angle, slope. FasNSeal® PolyPro® Common Vented Appliances. Select the appropriate Horizontal Termination Cap (see appliance manufacturer installation instructions). a direct vent heater system by a major testing agency such as UL, AGA, CGA, OMNI, or Warnock Hersey. An 8" adjustible length46VDA08AB was added to the vertical run and a 90 degree 46DVAe90B was added to complete the install. For vertical gas stove installations, measure the height from the stove outlet to the ceiling to determine the length of black pipe required. Either way you will put a bead of high temperature silicone around the inside of the first section that connect to the stove. Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation. Select the proper flashing and storm collar. DuraTech® Canada; Non-Canada. Some installations will require the use of a stove adapter. More Buying Choices $70.63 (7 new offers) Simpson Duravent 58DVA-E45 5x8" Direct Vent Galvanized 45 Degree Elbow. ClearancesSpecified by the appliance manufacturer. Stunning design and Engineered Excellence® utilizing state-of-the art manufacturing. In this installation we used a 48" 46DVA48B to start the chimney. We prioritize maintaining highest quality products, and providing excellent service to our end customers, and our distributors. })(); Low-profile locks and no hems or beads allow for a beautiful product that looks elegant in any interior. The inner and outer pipe diameters should match the outlet size of the appliance. DirectVent® Pro features tight inner connections for superb performance, with no gaskets or sealants required (unless specified by the appliance manufacturer). Check with your appliance manufacturer for approval.Â. DirectVent Pro features tight inner connections for superb performance, with no gaskets or sealants required (unless specified by the appliance manufacturer). thena decorative cover was placced over the wall thimble 46DVA-DC. Part: DuraVent 46DVA-HC. Buy the DuraVent DirectVent Pro High Wind Cap Termination Kit with 3 Inch and 4 Inch Flex Lengths Direct Vent Pipe For Gas Fireplaces & Gas Stoves. How to install DuraVent direct vent gas pipe. Use proper support and bracing. ; Page 2 A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. Important: Check the manufacturer’s rating plate and instruction manual to confirm that the DuraVent direct vent system is approved for use on the brand name appliance you have selected. How to install DuraVent direct vent gas pipe, Connecting Chimney brushes and tools to Rods, How to install a flashing on a metal roof, Submit your Chimney Installation Planning Worksheet, How to Install A DuraTech Insulated Chimney Pipe, How to Install a DVL Double Wall Stove Pipe, Cathedral Ceiling Support Box Ceiling Pitch Sizing Chart. Simpson DuraVent DirectVent Pro Simpson DuraVent offers one product to fulfill all of your direct venting needs. Fan DuraVent polypro Installation Instructions Manual. Engineered Excellence® with innovation and style…DirectVent® Pro. Page 1 Installation Instructions Round and Oval Type B GasVent Systems for use with natural as or liquid propane category I and draft hood equipped appliances and appliances listed to use Type B Gas Vent. Quality Products. chimney system. Important: Check the manufacturer’s rating plate and instruction manual to confirm that the DuraVent direct vent system is ap-proved for use on the brand name appliance you have selected. All black pipe lengths, pipe extensions, and elbows feature laser-welded outer wall seams for a sleek finish. Installation. DuraVent's direct vent is specified exclusively by nearly every major stove and fireplace manufacturer in the U.S. and Canada, with the largest choice of termination caps for direct vent available. Since 1960. DuraVent Authorized Dealer. Installation instructions can be viewed online at www.duravent.com, under Catalogs and Instructions. Check your owners manual for approved chimney companies, and other restrictions such as distance for a horizontal run. .018″ galvanized steel outer wall. ; Learn how to install a direct vent pipe. var xmlHttp = new XMLHttpRequest(); Check the appliance manufacturer’s installation instructions to confirm which types of vent configurations are permitted (i.e. Other options New from $42.70. We have provided illustrations of some typical direct vent chimney installations. Select a ceiling support/wall thimble cover or a cathedral ceiling support box. For horizontal installations, check the appliance manufacturer’s instructions for minimum rise and maximum horizontal run. Follow local building codes and have your venting system inspected. Get it as soon as Wed, Nov 11. Check your owners manual for approved chimney companies, and other restrictions such as distance for a horizontal run. DuraVent's direct vent products are designed for gas, propane stoves, heaters, and fireplaces. Home › Installation. Mid Efficiency, M&G DuraVent Duravent DirectVent Pro Direct Vent Pipe, Galvanized, Length: 24", Black. In general, Duravent louvers are manufactured 1/4" under measured dimensions, to allow 1/8" gap all around. Important: Check the manufacturer’s rating plate and instruction manual to confirm that the DuraVent direct vent system is approved for … DuraVent DirectVent Pro is a coaxial (concentric- pipe within a pipe) venting system designed for use with direct vent natural gas or propane stoves, heaters, and fireplaces. Gaskets or sealants not required (unless specified by the appliance manufacturer). For proper support, use elbow straps with offsets. The inner pipe exhausts the flue gases to the outside while the space between the inner and outer pipes brings in outside air that is used for the appliance's combustion. This will keep DuraVent DirectVent as the most preferred brand of direct vent in the market. © ExpressFireplace.com. A bead of high temperature silicone was added around the exterior edge of the wall thimble. NOTE: Refer to Duravent’s Typical Venting Installation drawings to select the appropriate component parts for your installation. Enjoy the videos and music you love, upload original content, and share it all with friends, family, and the world on YouTube. Simpson Dura-Vent Duravent 58DVA-36 5x8 Direct Vent Galvanized Pipe 36" 5.0 out of 5 stars 3. Materials and Construction.020″ aluminum inner wall. Determine the minimum height above the roof. Stand-Alone Installation. The owner's manual will tell you if you need to use one or if you can start off with the pipe as we did in this installation. ListingsDirectVent Pro, in combination with the gas appliance, has been tested and listed as a decorative gas appliance system or as a direct vent heater system by a major testing agency, such as UL, CSA, Warnock Hersey, or OMNI. Part: DuraVent 46DVA-CL34. $72.89 $ 72. DuraVent Type B Venting Installation Guide Simpson Dura-Vent's Type B Gas Vent system is for use with natural gas or liquid propane category I and draft hood equipped appliances, and appliances tested and listed to use Type B Gas Vent for a wide range of applications, including: natural gas fireplaces, gas-fired Learn more about our company Our Products DuraVent offers over twenty different product lines for … Painted outer walls made of laserwelded .018″ galvalume steel. To determine the length of galvanized pipe required, measure the ceiling thickness and the vertical rise in an attic or second story. An 18" length 46DVA18B was added to the horizontal cap and the other half of the wall thimble was added. Be fire safe! Measure the roof pitch. Mid Effeciency, Oil. A system designed and built to exhaust gas burning appliances listed as Direct Vent decorative gas appliances. Mid Efficiency, Natural Gas / Propane, Stand-Alone Installation. Find info on price, dimensions, installation and accessories. DuraVent 46DVA-CL33H 4" x 6-5/8" Inner Diameter - DirectVent Pro Direct Vent Pip, Galvanized. (function () { chimney system. Installation instructions can be viewed online at www.duravent.com, under Catalogs and Instructions. var BCData = {"csrf_token":"bc4625b6d9ef473dd261e2a09b6ab99258baafd162f77169ac7f831588c63f46"}; Following is a typical installation for a duravent direct vent chimney system installation. Contains more information on DirectVent Pro® Inner pipe exhausts flue gases to the outside. Check appliance manufacturer’s instructions for wall thimble and firestop requirements. Joe shows you how to install DuraTech DVL Double Wall Stove Pipe. Powered by BigCommerce. FREE Shipping. Single-wall gas vent system for category ii & iv gas-burning appliances (16 pages) Summary of Contents for DuraVent duraplus. Always follow DuraVent Installation instructions enclosed with the cap or support box before installing your chimney system. All DuraVent Type B Gas Vent; 3" DuraVent Type B Gas Vent ; 4" DuraVent Type B Gas Vent; ... A through-the-wall installation will require additional components (Wall Thimble, Tee w/ Cap, Tee Support, and Wall Straps). Important: Check the manufacturer’s rating plate and instruction manual to confirm that the Simpson Dura-Vent direct vent DRAVENT DIRECT VENT PRO www.duravent.com To protect vinyl siding, select vinyl siding standoff. The DuraVent Direct Vent System is an engineered product that has been designed and tested for use with an approved list of direct vent gas appliances. Chimney Installation. Simpson Dura-Vent warranty will be voided, and serious fire, health, or other safety hazards may result from any of the following actions: • Installation of any damaged Direct Vent component. CVS® Provides … DirectVent Read More » Important: Check the manufacturer’s rating plate and instruction manual to confirm that the DuraVent direct vent system is ap-proved for use on the brand name appliance you have selected. We used the screw provided with the pipe #8 1/2" length. IT IS OF THE UTMOST IMPORTANCE THAT TYPE B GAS VENT … If a different gap or no undersizing is required, please indicate so at time of order. DirectVent Pro is designed for use with direct vent stoves, heaters, and fireplaces. DuraVent Authorized Dealer. 70. xmlHttp.setRequestHeader('Content-Type', 'application/json'); COMMON VENT KIT (PVC AND DURAVENT) PRINTED 0317 100280793_2000539084 Contents ... common direct vent kit. At North Country Fire we strive to provide the best customer care including industry leading technical support. Check the manufacturer’s rating plate and instruction manual to confirm that the DuraVent Direct Vent is approved for use on the brand name appliance you have selected. the stove in the following illistration didn't require one. Outer pipe brings combustion air to the appliance. FasNSeal® 80/90; Tanked Water Heater. WHAT IS DIRECT VENT? Type B Gas Vent; Common Vented (High plus low-mid efficiency appliances paired into one vent) Mid Efficiency, Natural Gas / Propane, Stand-Alone Installation. document.getElementById("copyright_year").innerHTML = new Date().getFullYear(); Use wall straps for long vertical runs. A snorkel termination may be used if height restrictions prevent adequate rise above the appliance. Theme designed by Papathemes. 89. All black xmlHttp.open('POST', '/events/trigger-visit-event'); IMPORTANT Read all instructions carefully before starting the installation. Click Here http://www.northlineexpress.com/ to see all of our Chimney Pipe. Please visit duravent.com. The 8" adjustible was screwed in place with self tapers. Also, check for any venting restrictions such as maximum horizontal run, minimum and maximum vertical rise, maximum offset, etc. DURAVENT DIRECT VENT PRO www.duravent.com Reise Ast 06 • Relaes May 05 ECCO Supply™ www.eccosupply.ca 13-1 Expert Service. $44.70 $ 44. 4.7 out of 5 stars 4. Following is a typical installation for a duravent direct vent chimney system installation. Direct Vent Pro chimney systems feature state of the art engineering and manufacturing. Installation instructions can be viewed online at www.duravent.com, under Catalogs and Instructions. Previous Next Consistently the first to market with new innovations in venting systems, DuraVent has captured a leadership position in emerging markets. Installation instructions can be viewed online at www.duravent.com, under Catalogs and Instructions. The venting is part of a sealed and balanced system with an air intake and exhaust designed into the venting.This type of venting system is a component of the appliance manufactures listed system. Only 7 left in stock - order soon. FasNSeal® 80/90; Oil Furnace / Boiler. ApplicationsDirectVent® Pro is a unitized, coaxial (concentric) venting system designed for use with direct vent gas or propane stoves, heaters, and fireplaces. We believe these changes will help with installation and performance of your direct vent installations. At North Country Fire we strive to provide the best customer care including industry leading technical support. DirectVent Pro Installation Guide DirectVent Pro by Simpson Duravent is a unitized, coaxial venting system designed for use with direct vent gas or propane stoves, heaters, and fireplaces. Maintain at least the minimum clearances (air-space) between the vent pipe and nearby combustibles, as specified in the appliance manufacturer’s installation instructions. NYSERDA Rebate Up To $2,500 Off New Pellet Stove. DuraVent Direct Vent Pro 5 8" DuraVent Type B Gas Vent . Type B Gas Vent; Common Vented (High plus low-mid efficiency appliances paired into one vent) Mid Efficiency, Natural Gas / Propane, Stand-Alone Installation. Always follow DuraVent Installation instructions enclosed with the cap or support box before installing your chimney system. The wall thimble was put on the exterior and the cap was added to the wall thimble. Installation instructions can be viewed online at www.duravent.com, under Catalogs and Instructions. DuraVent’s direct vent is specified exclusively by nearly every major stove and fireplace manufacturer in the U.S. and Canada, with the largest choice of termination caps for direct vent available. Copyright © 2020 - Leaders in-Venting InnovationTM, DirectVent® Pro  NEW Horizontal Vent Kit for DV Inserts, DirectVent® Pro Horizontal Termination DVA-H2, Pro Française Instructions d’installation, Pro Instructions: Converting A Class-A Metal Chimney or A Masonry Chimney to A DirectVent, Pro Horizontal Colinear Reline Kit Installation InstructionsÂ, Changes to DuraVent DirectVent® Pro Galvanized Steel Pipe, Montigo now Approved with 5″ x 8″ DirectVent. If an offset is required to avoid obstructions, use a pair of 45° elbows. DirectVent Pro Installation Instructions DIY Fireplace Installation - Flexible Direct Vent - YouTube The following design recommendations are general guideline to assist in the design and selection of venting components for your installation. Find info on price, dimensions, installation and accessories. FREE Shipping by Amazon. Attic Insulation Shield is required in attic. xmlHttp.send('{"initiator":{"id":"","session_id":"25c9959c05c89958a5d6e40c53c199389b81bd53","type":"ANONYMOUS","visit_id":"452a0855-0895-409c-acb4-609f2e2e22f5","visitor_id":"7382dc12-efec-487e-8da9-a0579b195209"},"referer":{"url":"http:\/\/www.expressfireplace.com\/how-to-install-duravent-direct-vent-gas-pipe\/"},"request":{"url":"http:\/\/www.expressfireplace.com:443\/how-to-install-duravent-direct-vent-gas-pipe\/"}}'); Caps also available in stainless steel and copper. • Unauthorized modification of the Direct Vent System • Installation of any component part not manufactured or approved by Simpson Dura-Vent. If you have any questions, please contact your local DuraVent Regional Manager. horizontal, vertical, chimney reline, etc.). The DuraVent warranty will be voided, and serious fire, health, or other safety hazards may result from any of the following actions: • Installation of any damaged Direct Vent component. Tight inner connections offer superb performance without the use of gaskets or sealants (unless specified by the appliance manufacturer) making Direct Vent Pro not only an industry leader in innovation also but easy to install. Canada Only. Buy the DuraVent DirectVent Pro Square Horizontal Termination Cap Direct Vent Pipe For Gas Fireplaces & Gas Stoves. Firestops are required at each floor level beyond the first floor ceiling support/wall thimble cover or cathedral ceiling support box.
2020 duravent direct vent installation